Line 131: |
Line 131: |
| | | |
| | | |
− | It would appear that you cannot rename the VolumeGroup on a SME 7 installation with the SME 8 CD
| + | With SME 8 being based on CentOS 5, assembling the RAID in rescue mode must be specified using the disk's UUID. If you have the SME 7 CD it will be easier to rename the Volume Group using it per the instructions below. Otherwise use the SME 8 procedure. |
| | | |
| {{Note box|Before you start, It might be worth fscking the disk/s to ensure that there are no errors.}} | | {{Note box|Before you start, It might be worth fscking the disk/s to ensure that there are no errors.}} |
Line 137: |
Line 137: |
| # Make sure you have a very good backup | | # Make sure you have a very good backup |
| # signal-event pre-backup on the old installation | | # signal-event pre-backup on the old installation |
− | # Boot with a SME7 CD and only one of your original disks (in the case of a RAID1 arrangement) | + | # Boot with a SME7 CD or SME 8 CD and only one of your original disks (in the case of a RAID1 arrangement) |
| # As per instructions in "Boot from SME Server 7.1 (or newer) install CD" above : | | # As per instructions in "Boot from SME Server 7.1 (or newer) install CD" above : |
| | | |
Line 144: |
Line 144: |
| Note: don't start the network and skip mounting the filesystem. | | Note: don't start the network and skip mounting the filesystem. |
| | | |
| + | If using SME 7 CD |
| mdadm -AR /dev/md5 /dev/hdx2 | | mdadm -AR /dev/md5 /dev/hdx2 |
| + | |
| + | If using SME 8 CD |
| + | mdadm --examine /dev/sda# | grep 'UUID' |
| + | mdadm -AR --uuid '''the:uuid:value:from:above''' /dev/md5 |
| + | |
| + | Next Steps |
| lvm vgscan | | lvm vgscan |
| lvm vgs -v | | lvm vgs -v |
Line 150: |
Line 157: |
| lvm vgrename orig_vg_name new_vg_name | | lvm vgrename orig_vg_name new_vg_name |
| exit | | exit |
| + | |
| | | |
| Now remove the CD and reboot into SME 8 : | | Now remove the CD and reboot into SME 8 : |