Clarified default configuration under SME
Line 7: Line 7:     
==Default Configuration (USB)==
 
==Default Configuration (USB)==
Most USB connected UPS's will work with the default settings. If using a USB connection just enable nut as follows:
+
The default configuration in SME Server as set by the database properties for 'nut' is
 +
Model = usbhid-ups
 +
status = disabled
 +
type = service
 +
{Note box|Absence of a 'Master' property setting defaults the configuration to being a Master setup. That is a UPS connected directly to the server via USB or serial cable is assumed. See later for setting as a Slave.
 +
 
 +
The default is for nut to be disabled, that is no UPS connected}
 +
 
 +
Most USB connected UPS's will work with these default settings. If using a USB connection just enable nut as follows:
    
  config setprop nut status enabled
 
  config setprop nut status enabled
Line 13: Line 21:  
  signal-event reboot
 
  signal-event reboot
   −
If your USB UPS does not work properly OR you have a '''serial device''' then follow the Configuration Options below.
+
If your USB UPS does not work properly OR you have a '''serial device''' then follow the Configuration Options below as required.
    