Most USB connected UPS's will work with the default settings. If using a USB connection just enable nut as follows:
+
The default configuration in SME Server as set by the database properties for 'nut' is
+
Model = usbhid-ups
+
status = disabled
+
type = service
+
{Note box|Absence of a 'Master' property setting defaults the configuration to being a Master setup. That is a UPS connected directly to the server via USB or serial cable is assumed. See later for setting as a Slave.
+
+
The default is for nut to be disabled, that is no UPS connected}
+
+
Most USB connected UPS's will work with these default settings. If using a USB connection just enable nut as follows:
config setprop nut status enabled
config setprop nut status enabled
Line 13:
Line 21:
signal-event reboot
signal-event reboot
−
If your USB UPS does not work properly OR you have a '''serial device''' then follow the Configuration Options below.
+
If your USB UPS does not work properly OR you have a '''serial device''' then follow the Configuration Options below as required.