Uninterruptable Power Supply/fr

From SME Server
Revision as of 09:01, 17 January 2024 by Gieres (talk | contribs)
Jump to navigationJump to search


Is this article helpful to you?
Please consider donating or volunteering
Thank you!

Alimentation sans interruption - ASI

PythonIcon.png Skill level: Advanced
The instructions on this page may require deviations from standard procedures. A good understanding of linux and Koozali SME Server is recommended.


Introduction

L'objectif principal du projet Network UPS Tools (NUT) est de fournir une surveillance fiable du matériel d'ASI et d'assurer des arrêts sûrs des systèmes connectés.

La configuration par défaut de NUT maintiendra vos systèmes connectés opérationnels jusqu'à ce qu'un état critique de la batterie soit atteint (c'est-à-dire que la batterie soit presque vide), puis mettra hors tension votre serveur/équipement de manière contrôlée. Voir http://www.networkupstools.org/ (en anglais).

Si vous disposez d'un onduleur de marque APC, consultez également Uninterruptable_Power_Supply:APC (en anglais) pour une alternative à l'implémentation ordinaire Koozali SME « Nut ».

Si vous disposez d'une ASI Dell, cela pourrait vous aider Uninterruptable_Power_Supply:LatestGeekery (en anglais).

Configuration par défaut (USB)

La configuration par défaut pour 'NUT' dans le serveur Koozali SME est assurée par les propriétés de la base de données de configuration :

Model  = usbhid-ups
status = disabled
type   = service
Important.png Note :
l'absence d'une propriété 'Master' définit la configuration par défaut comme étant une configuration principale. Il s'agit d'un ASI connectée directement au serveur via un câble USB ou série. Voir plus tard pour le réglage en tant qu'esclave.

Par défaut, NUT est désactivé, c'est qu'il n'y a pas d'ASI connectée.


La plupart des ASI connectées en USB fonctionneront avec ces paramètres par défaut. Si vous utilisez une connexion USB, activez seulement NUT comme suit :

Pour Koozali SME 10, systemd est maintenant en service. Nous avons créé un service générique pour votre commodité :

config setprop nut status enabled
signal-event e-smith-nutUPS-update
systemctl restart nut-server.service
systemctl restart nut-monitor.service
systemctl restart nut.service
config setprop nut status enabled
signal-event post-upgrade
signal-event reboot

Si votre ASI USB ne fonctionne pas correctement OU si vous avez un appareil série, alors suivez les « Options de configuration » ci-après comme requises.

Configuration Options

Not all UPS's are supported by USB or the usbhid-ups driver. However NUT supports many UPS's and can be configured under SME Server easily.

Serial Connection

  1. Find the configuration details for your model of UPS. Refer to: http://www.networkupstools.org/stable-hcl.html and make note of the driver name and upstype number (if any) in the third column.
    Warning.png Warning:
    Always use the serial cable supplied with the UPS. Standard serial cables won't work with a serial UPS and have been known to cause damage to the UPS. Pay particular attention to any references to cable in in the UPS Model column.

  2. From the console issue the following commands: config setprop nut Model <model> config setprop nut Device <device> config setprop nut Type <type> config setprop nut status enabled Where:
    <model> and <type> are the driver name and type number found above.
    <device> is the serial port that the UPS is connected to eg. /dev/ttyS0. It also possible to use a more readable symlink. See HowTo on udev - symlinks for details. Note: The case of Model, Device and Type.
  3. Check: config show nut
  4. Apply changes and restart server: signal-event post-upgrade signal-event reboot Alternatively, without NUT running or requiring a server reboot: signal-event console-save service nut start
  5. Confirm server is communicating with UPS: upsc UPS@localhost Whenever a UPS event occurs Emails are sent to the admin account.

Configuring as a master

edit the file /etc/ups/nut.conf, and modify the line

MODE=netserver

Set configuration values:

config setprop nut access private TCPPort 3493 
expand-template /etc/ups/upsd.conf
expand-template /etc/rc.d/init.d/masq
systemctl restart masq
systemctl restart nut-server 

Configuring as a slave

Set configuration values:

config setprop nut SlaveUPS UPS@192.168.33.11
config setprop nut Master no

Where 192.168.33.11 is your UPS master, that is the computer that is in direct communication with the UPS. The hostname of that computer may also work.

Apply changes and restart server:

signal-event post-upgrade
signal-event reboot 

or (for SME10):

signal-event e-smith-nutUPS-update

Confirm server is communicating with master:

upsc UPS@192.168.33.11

Connecting multiple UPS's

To be added http://bugs.contribs.org/show_bug.cgi?id=629

<tabs container> <tab name="SME 9">


Warning.png Warning:
Be sure to have e-smith-nutUPS-2.4.0-9.el6.sme.noarch or higher to carry on with these instructions. If you get a lower version, just follow SME8 instruction.


rpm -qa e-smith-nutUPS

If you get NUT running with administrative privileges modification from sme8 instruction, you need to remove the custom template created for this. These variables are taken in charge by the new package.

First you need to delete the custom template file.( This command delete the directory, be sure you don't have personal file present. If the case, delete manualy the file created for administrative privileges )

rm -rf /etc/e-smith/templates-custom/etc/ups/upsd.users

Now, to get upsd to recognise the modification of user, we need to expand the template and reload the upsd configuration

/sbin/e-smith/expand-template /etc/ups/upsd.users
/usr/sbin/upsd -c reload 

Variables et commandes ASI

Dans certains cas, vous souhaiterez peut-être modifier les variables de l'onduleur lui-même, telles que le paramètre Low Charge/LOWBATTERY. Cela nécessite l'utilisation de la commande upsrw et les privilèges d'administrateur ASI.

Vous souhaiterez peut-être également contrôler l'onduleur directement à partir de la ligne de commande en émettant des commandes ASI. Cela nécessite l'utilisation de la commande upscmd et les privilèges d'administrateur ASI.

Warning.png Attention :
en général, les données de l'onduleur doivent rester protégées et les modifications ou l'émission de commandes doivent être effectuées avec attention. Si vous souhaitez apporter des modifications aux données ou émettre des commandes, les privilèges d'administrateur peuvent être activés comme ci-dessous et doivent ensuite être désactivés.



Droits d'administrateur ASI

Vous devriez vérifier votre nouveau mot de passe (AdminPass) pour exécuter upserw et upscmd. Bien sûr, vous pouvez changer votre mot de passe pour un mot de passe plus facile à utiliser.

config show nut

Pour mettre un nouveau mot de passe admin dans la base de données. Le nouveau mot de passe serait admin (changer comme vous voulez) :

config setprop nut AdminPass admin 

Pour activer les droits d'administrateur et exécuter des commandes à l'ASI :

config setprop nut AdminUser enabled

Maintenant, pour que upsd reconnaisse la modification de l'administrateur pour les droits d'administrateur, nous développons le modèle et rechargeons la configuration upsd.

/sbin/e-smith/expand-template /etc/ups/upsd.users
/usr/sbin/upsd -c reload 


Important.png Note :
pour désactiver les droits d'administrateur après avoir modifié les paramètres de l'ASI ou effectué les commandes nécessaires, exécutez les commandes :
config setprop nut AdminUser disabled
/sbin/e-smith/expand-template /etc/ups/upsd.users
/usr/sbin/upsd -c reload