Difference between revisions of "Talk:SANE"

From SME Server
Jump to navigationJump to search
(questions about 4300c)
Line 1: Line 1:
If you have fixed a request make here can you remove the comments so we can see what is still to be done
 
 
 
use templates not templates-custom
 
use templates not templates-custom
  
Line 8: Line 6:
 
you just need to work out what needs to change
 
you just need to work out what needs to change
  
:: Yes, I looked...
+
: Yes, I looked...
:: create a smeserver-sane with the templates: I don't have a lot of time at present
+
: create a smeserver-sane with the templates: I don't have a lot of time at present
:: If I have a little of time...
+
: If I have a little of time...
:: I must finish the installation of mgetty / vgetty for SME before  
+
: I must finish the installation of mgetty / vgetty for SME before  
  
 
good work so far, I'm dusting off my old scanner...
 
good work so far, I'm dusting off my old scanner...
:: What Manufacturer and Model?
+
: What Manufacturer and Model?
 
+
:: sane-find-scanner
:: I do not have a lot of place on my server and Shad still did not recover my src rpm.
+
:: found USB scanner (vendor=0x03f0 [Hewlett-Packard], product=0x0305 [Hewlett-Packard ScanJet 4300C]) at libusb:002:003
:: Tomorrow I remove source of my server
+
:: and lsusb > Bus 002 Device 003: ID 03f0:0305 Hewlett-Packard ScanJet 4300c
:: [[User:Ecureuil|Ecureuil]]
+
:: but scanimage -L > No scanners were identified.
 
+
:: documentation suggest this may not be a problem if i can supply my device name
----
+
:: could you suggest what the syntax might be ?
Hi Cactus,
+
:: http://www.sane-project.org/sane-mfgs.html#Z-HEWLETT-PACKARD > niash driver
 
 
I don't understand:
 
  After succesfull of the required packages issue the following commands:
 
 
 
  signal-event post-upgrade
 
  signal-event reboot
 
It isn't very good, it takes of 'CPU  time '
 
 
 
Ecureuil
 
 
 
:What do you mean by that I do not understand your remark. Above commands are normal (required) steps after installing software using yum on the SME Server shell. - [[User:Cactus|Cactus]] 05:41, 4 April 2008 (MDT)
 
  
== Stick to SME Server default syntax and naming conventions please ==
 
  
Thank you for providing this Howto I think a lot of users will like this in the future, but I modified your English version and I noticed you have changed some items back. IMHO you should not have done so as I made changes to make things more conform to the SME Server naming conventions and you should have adapted them in your other translation(s) as well.
 
  
A service normally is a daemon, hence the database record should be named saned (or sane) and not sane-port. On top of that I think it is also strange to call the group the server is configured to use to be saned, I therefore changed it to ''saneusers'' in the example to avoid confusion between users and the SANE daemon (which is normally referenced as saned).
+
: View sane documentation: service = sane-port => grrrrrrrrrrrrrrr
- [[User:Cactus|Cactus]] 05:49, 4 April 2008 (MDT)
 
:: I don't speak english very good
 
:: Do not change anything without understanding and reading
 
:: View sane documentation: service = sane-port => grrrrrrrrrrrrrrr
 
:: http://www.sane-project.org/man/saned.8.html
 
:: http://penguin-breeder.org/sane/saned/
 
:: thank you
 
::
 
:: Another problem:
 
:: If xinetd start, ' saned - d128 ' will not be able to work
 
:: I prefer the French version for it.
 
::
 
:: for signal-event post-upgrade and signal-event reboot:
 
:: The post upgrade and the reboot process are only needed for smeserver
 
:: packages using the template system. As sane-backend nor xinetd are
 
:: smeserver specific, we don't need these (expensive !) steps.
 
  
:: [[User:Ecureuil|Ecureuil]]
+
:: don't take offense, that is the nature of wiki, just make the change and if someone is wrong change it back with an explaination, which is what you do [[User:Snoble|Snoble]] 19:59, 4 April 2008 (MDT)

Revision as of 02:59, 5 April 2008

use templates not templates-custom

create a smeserver-sane with the templates

see http://wiki.contribs.org/HylaFax for an alternative to a full reconfig/reboot, you just need to work out what needs to change

Yes, I looked...
create a smeserver-sane with the templates: I don't have a lot of time at present
If I have a little of time...
I must finish the installation of mgetty / vgetty for SME before

good work so far, I'm dusting off my old scanner...

What Manufacturer and Model?
sane-find-scanner
found USB scanner (vendor=0x03f0 [Hewlett-Packard], product=0x0305 [Hewlett-Packard ScanJet 4300C]) at libusb:002:003
and lsusb > Bus 002 Device 003: ID 03f0:0305 Hewlett-Packard ScanJet 4300c
but scanimage -L > No scanners were identified.
documentation suggest this may not be a problem if i can supply my device name
could you suggest what the syntax might be ?
http://www.sane-project.org/sane-mfgs.html#Z-HEWLETT-PACKARD > niash driver


View sane documentation: service = sane-port => grrrrrrrrrrrrrrr
don't take offense, that is the nature of wiki, just make the change and if someone is wrong change it back with an explaination, which is what you do Snoble 19:59, 4 April 2008 (MDT)