Difference between revisions of "Talk:Raid"
From SME Server
Jump to navigationJump to searchLine 16: | Line 16: | ||
to send warning to admin. append the '''-m admin''' directive to DEVICESCAN in the config file | to send warning to admin. append the '''-m admin''' directive to DEVICESCAN in the config file | ||
nano -w /etc/smartd.conf | nano -w /etc/smartd.conf | ||
− | DEVICESCAN -m admin | + | DEVICESCAN -m admin |
Revision as of 07:04, 27 October 2007
We could add a section on enabling smartd to monitor disk health
see http://bugs.contribs.org/show_bug.cgi?id=1445
http://www.linuxmanpages.com/man8/smartd.8.php
Monitor Disk Health
Self-Monitoring, Analysis and Reporting Technology (SMART) is built into many ATA-3 and later ATA, IDE and SCSI-3 hard drives. The purpose of SMART is to monitor the reliability of the hard drive and predict drive failures, and to carry out different types of drive self-tests.
To enable
config set smartd service config setprop smartd status enabled ln -s /etc/rc.d/init.d/e-smith-service /etc/rc.d/rc7.d/S40smartd
This will log warnings to /var/log/messages.
to send warning to admin. append the -m admin directive to DEVICESCAN in the config file
nano -w /etc/smartd.conf DEVICESCAN -m admin