Difference between revisions of "SME Server 9.2 Addendum"

From SME Server
Jump to navigationJump to search
(e-smith-base update)
 
m
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
 
=====No external network access when using bonding=====
 
=====No external network access when using bonding=====
If you are using bonding of two network interfaces (e.g. server-only with two indentical network adapters) the default route to the gateway  is not created.
+
If you are using bonding of two network interfaces (e.g. server-only mode with two indentical network adapters) the default route to the gateway  is not created.
 
to check if you have any bonding on your server:
 
to check if you have any bonding on your server:
 
  # ifconfig |grep bond
 
  # ifconfig |grep bond
 
If it returns something then you have bonding.
 
If it returns something then you have bonding.
This is fixed in e-smith-base-5.6.0-31.el6.sme.noarch.rpm available in smeupdates since May the 4th, 2017.You can use 'yum update' to upgrade to the latest version of e-smith-base.
+
This is fixed in e-smith-base-5.6.0-31 available in smeupdates since May the 4th, 2017. You can use 'yum update' to upgrade to this latest version of e-smith-base.
  
If you upgraded from SME Server 9.1 to 9.2.0 and do not have network connection, you should perform the following:
+
If you upgraded from SME Server 9.1 to 9.2.0 and do not have a network connection, you should perform the following:
 
  route add default gateway `db configuration get GatewayIP`
 
  route add default gateway `db configuration get GatewayIP`
 
  yum update e-smith-base  
 
  yum update e-smith-base  
 
  signal-event post-upgrade; signal-event reboot
 
  signal-event post-upgrade; signal-event reboot
 
Replace `db configuration get GatewayIP` by your gateway IP if you know it, but this command should give the value you previously configured).
 
Replace `db configuration get GatewayIP` by your gateway IP if you know it, but this command should give the value you previously configured).
 +
 +
[[Category:SME Server Releases]]

Latest revision as of 17:45, 5 May 2017

No external network access when using bonding

If you are using bonding of two network interfaces (e.g. server-only mode with two indentical network adapters) the default route to the gateway is not created. to check if you have any bonding on your server:

# ifconfig |grep bond

If it returns something then you have bonding. This is fixed in e-smith-base-5.6.0-31 available in smeupdates since May the 4th, 2017. You can use 'yum update' to upgrade to this latest version of e-smith-base.

If you upgraded from SME Server 9.1 to 9.2.0 and do not have a network connection, you should perform the following:

route add default gateway `db configuration get GatewayIP`
yum update e-smith-base 
signal-event post-upgrade; signal-event reboot

Replace `db configuration get GatewayIP` by your gateway IP if you know it, but this command should give the value you previously configured).