Difference between revisions of "Virtual SME Server"
Unnilennium (talk | contribs) |
|||
(4 intermediate revisions by the same user not shown) | |||
Line 126: | Line 126: | ||
*Interesting [http://pve.proxmox.com/wiki/SMEServer_KVM article] on installing SME Server as guest on Proxmox | *Interesting [http://pve.proxmox.com/wiki/SMEServer_KVM article] on installing SME Server as guest on Proxmox | ||
− | ===SME | + | ===SME on Proxmox at Online.net=== |
This is based on work by Daniel here: https://wikit.firewall-services.com/doku.php/tuto/virtualisation/netwok_conf_sur_dedibox | This is based on work by Daniel here: https://wikit.firewall-services.com/doku.php/tuto/virtualisation/netwok_conf_sur_dedibox | ||
Line 147: | Line 147: | ||
*10:10:00:00:20:20 - you DID set the MAC didn't you ? | *10:10:00:00:20:20 - you DID set the MAC didn't you ? | ||
− | {{Note box|Proxmox now have a single IP you can use for all your VMs : 62.210.0.1}} | + | {{Note box|Proxmox now have a single Gateway IP you can use for all your VMs : 62.210.0.1}} |
===Proxmox configuration=== | ===Proxmox configuration=== | ||
Line 171: | Line 171: | ||
It doesn't matter which one is 0 or 1 as long as the settings are correct. | It doesn't matter which one is 0 or 1 as long as the settings are correct. | ||
− | + | You might want to edit your /etc/network/interfaces | |
+ | auto vmbr1 | ||
+ | iface vmbr1 inet manual | ||
+ | bridge-ports none | ||
+ | bridge-stp off | ||
+ | bridge-fd 0 | ||
+ | post-up echo 1 > /proc/sys/net/ipv4/ip_forward | ||
+ | # we assume external interface is eno1 here, adapt accordingly | ||
+ | post-up echo 1 > /proc/sys/net/ipv4/conf/eno1/proxy_arp | ||
+ | post-up echo 1 > /proc/sys/net/ipv4/conf/vmbr1/proxy_arp | ||
+ | post-up echo 1 > /proc/sys/net/ipv4/conf/vmbr1/forwarding | ||
+ | #uniq ip | ||
+ | post-up /sbin/ip route add VMIP.VMIP.VMIP.VMIP dev vmbr1 | ||
+ | pre-down /sbin/ip route del VMIP.VMIP.VMIP.VMIP | ||
+ | # multiple routable IP subnet example | ||
+ | post-up /sbin/ip route add VMIP.VMIP.VMIP.VMIP/29 dev vmbr1 | ||
+ | pre-down /sbin/ip route del VMIP.VMIP.VMIP.VMIP | ||
After setup you can run: | After setup you can run: | ||
Line 180: | Line 196: | ||
signal-event post-upgrade;signal-event reboot | signal-event post-upgrade;signal-event reboot | ||
− | + | ===SME Configuration=== | |
+ | Now do your standard SME installation. | ||
+ | |||
+ | <tabs container><tab name="For SME 10"> | ||
+ | * Install SME using ISO | ||
+ | * choose install mode without LVM and RAID add this on boot options: nolvm noraid | ||
+ | * Optionally you could use the Disk tool at the second screen if you want to put /home/e-smith/files in a different disk. | ||
+ | * Enter the console at the end of installation. | ||
+ | ** set admin password | ||
+ | ** set domain and hostname | ||
+ | ** choose server-gateway (do not use server only if you use an IP accessible directly from the internet because Firewall is not designed for that in Server-Mode) | ||
+ | ** LAN: choose the dummy interface if you only have an interface, or the appropriate one for LAN | ||
+ | ** LAN: use all suggested setting or adapt to your needs | ||
+ | ** WAN: choose static mode | ||
+ | ** WAN: set the dedicated IP | ||
+ | ** WAN: set the Netmask with either 255.255.255.255 or 0.0.0.0 (MASK includes only your IP or MASK includes all IPs) | ||
+ | ** WAN: set the Gateway IP (as the Gateway will be quite different from the Server IP you need to have the MASK set as shown above to have it accepted. | ||
+ | |||
+ | signale-event post-upgrade; signal-event reboot | ||
− | + | enjoy | |
− | |||
+ | </tab> | ||
+ | <tab name="For SME 8"> | ||
<here would be a lot easier if we could force it to have a local IP first so you could ssh from Proxmox to SME and you could then use scp to copy files or a terminal to copy and paste> | <here would be a lot easier if we could force it to have a local IP first so you could ssh from Proxmox to SME and you could then use scp to copy files or a terminal to copy and paste> | ||
Line 270: | Line 305: | ||
LocalNetmask=255.255.255.0 | LocalNetmask=255.255.255.0 | ||
− | = | + | </tab><tab name="For SME 9"> |
Things have changed slightly for v9 | Things have changed slightly for v9 | ||
Line 291: | Line 326: | ||
Note that you will not see MAC addresses in the Internal Interface settings as you did in v8 | Note that you will not see MAC addresses in the Internal Interface settings as you did in v8 | ||
+ | </tab> | ||
+ | </tabs> | ||
==Xen== | ==Xen== |
Latest revision as of 04:00, 1 September 2022
SME Server as a virtualized Guest server
Examples: Available Virtual Machine hosts
Infrastructure-level
- Proxmox VM Community edition
- Linux KVM (Red Hat developed, available with various managment tools also on CentOS, Debian, Ubuntu etc.)
- VMWare Enterprise (not free)
- Citrix (not free)
Desktop-level
- VirtualBox
- VMWare workstation (not free)
- VMWare Fusion (Apple) (not free)
- Parallels (Apple) (not free)
- Linux KVM
Cloud Hosting
There are many different offerings, too many to explore here.
In general, setup, requirements and management will be similar for most of the above.
Considerations
- Storage: Local, NAS, iSCSI, LVM, Raid
- Network: LAN/WAN, VLAN, VPN, Bandwith,
- Out of band access (VNC, SPICE)
'Hardware' configuration of a Virtual SME Sever
CPU
- Host CPU or emulate
On Proxmox Host CPU mode is the most performant, but is self-evidently restrictive if you intend to be able to move the VM to a host with different host architecture!.
- Sockets and cores
Althose two sockets with one core and one socket with two cores produces the same number of cores, it may be treated differently by server licensing (e.g. Windows). This consideration does not apply to Koozali SME Server as a guest: one socket and multiple cores is typically chosen.
Memory options
- To balloon or to not to balloon: for Linux guests yes, at present avoid for WIndows guests
Disk options
- Virtio driver or legacy driver: On Proxmox for Linux use VirtIO
- Disk types pros and cons
- Disk I/O options
Network options
- Virtio driver or legacy driver?
- Bridge, NAT or Route?
- Bandwidth options
Cloning a virtual SME Server
When you clone a virtual SME server, you might want to reset some unique variables on the cloned machine. Several things (will) have changed like install date and MAC addresses. Visualization platforms will automatically change the MAC addresses of the NIC's for the cloned machine.
After cloning and first boot, log in as root and issue the following commands
config delprop sysconfig SystemID config setprop sysconfig InstallEpoch `date +%s` rm -f /etc/udev/rules.d/70-persistent-net.rules
Then run the console application and reconfigure the server to your wishes, where you must perform a signal-event post-upgrade; signal-event reboot for all changes to take effect.
Installation options of a Virtual SME Server
Kernel options
SME Server configuration settings
NTPD
Timing related options are important within Virtual Guests and to the amount of 'pressure' it puts on the host and level/increasing CPU usage of the host and guest. By default SME Server uses the NTP deamon for 'timing' related matters, but by default is focussed on the above mentioned 1000HZ, hence the kernel option 'divider=10', thus reducing the timing cycles/context switching requests on the host. See the above VMWare document mentioned (Way at the bottom).
On a Virtual SME guest server the ntpd SupportLargeDrift DB variable can be enabled as follows:
config setprop ntpd SupportLargeDrift enabled expand-template /etc/ntp.conf
and
service ntpd restart
to activate the new configuration. This will adjust /etc/ntp.conf to 'better' settings for a virtual guest. By setting the above value to 'disabled' and expand the template, the NTP service and configuration will revert back to SME Server defaults.
Clock/frequency
As per suggestions in this article from VmWare and this one from Oracle on virtual Linux Guests, adjusting the guest Frequency will improve the guests speed.
You can check if your guest server can benefit from these boot options:
[root@sme8 ~]# grep CONFIG_HZ /boot/config-`uname -r` # CONFIG_HZ_100 is not set # CONFIG_HZ_250 is not set CONFIG_HZ_1000=y CONFIG_HZ=1000
If you see the above result, these boot options are useful.
For example, if your kernel boot line is:
kernel /vmlinuz-2.6.18-348.6.1.el5 ro root=/dev/main/root
change it to:
kernel /vmlinuz-2.6.18-348.6.1.el5 ro root=/dev/main/root divider=10 clocksource=acpi_pm
Tools/utilities
iotop
top like utility to monitor the guest I/O (performance)
yum install iotop
cpu info
Detailed info on the guest cpu(s)
cat /proc/cpuinfo
Proxmox
- Interesting article on installing SME Server as guest on Proxmox
SME on Proxmox at Online.net
This is based on work by Daniel here: https://wikit.firewall-services.com/doku.php/tuto/virtualisation/netwok_conf_sur_dedibox
Online.net configuration
Some assumptions:
- Your main Proxmox server IP address
- IP address 62.20.20.250
- Netmask 255.255.255.0
- Gateway 62.20.20.1
- Your secondary IP address
- 200.30.30.1
- 10:10:00:00:20:20 - you DID set the MAC didn't you ?
Proxmox configuration
We will use the vmbr0 that is set up, but we need to create a dummy one so we can put SME in server/gateway mode and use Daniels scripts:
- Create a new network interface and call it vmbr1
- Do NOT set IP address/subnet/bridge ports etc.
- Create your KVM for SME. Make sure that you give it two network adaptors - one is vmbr0 and one is vmbr1
- vmbr0 should have the following settings :
- Model: virtio
- MAC: 10:10:00:00:20:20 (as per your mac that you set)
- After you have created the KVM add a second adaptor:
- vmbr1 should have the following settings:
- Model: virtio
- MAC: should be the MAC of your main IP address
It doesn't matter which one is 0 or 1 as long as the settings are correct.
You might want to edit your /etc/network/interfaces
auto vmbr1 iface vmbr1 inet manual bridge-ports none bridge-stp off bridge-fd 0 post-up echo 1 > /proc/sys/net/ipv4/ip_forward # we assume external interface is eno1 here, adapt accordingly post-up echo 1 > /proc/sys/net/ipv4/conf/eno1/proxy_arp post-up echo 1 > /proc/sys/net/ipv4/conf/vmbr1/proxy_arp post-up echo 1 > /proc/sys/net/ipv4/conf/vmbr1/forwarding #uniq ip post-up /sbin/ip route add VMIP.VMIP.VMIP.VMIP dev vmbr1 pre-down /sbin/ip route del VMIP.VMIP.VMIP.VMIP # multiple routable IP subnet example post-up /sbin/ip route add VMIP.VMIP.VMIP.VMIP/29 dev vmbr1 pre-down /sbin/ip route del VMIP.VMIP.VMIP.VMIP
After setup you can run:
config set GatewayIP 62.210.0.1
/etc/e-smith/events/actions/update-ifcfg signal-event post-upgrade;signal-event reboot
SME Configuration
Now do your standard SME installation.
- Install SME using ISO
- choose install mode without LVM and RAID add this on boot options: nolvm noraid
- Optionally you could use the Disk tool at the second screen if you want to put /home/e-smith/files in a different disk.
- Enter the console at the end of installation.
- set admin password
- set domain and hostname
- choose server-gateway (do not use server only if you use an IP accessible directly from the internet because Firewall is not designed for that in Server-Mode)
- LAN: choose the dummy interface if you only have an interface, or the appropriate one for LAN
- LAN: use all suggested setting or adapt to your needs
- WAN: choose static mode
- WAN: set the dedicated IP
- WAN: set the Netmask with either 255.255.255.255 or 0.0.0.0 (MASK includes only your IP or MASK includes all IPs)
- WAN: set the Gateway IP (as the Gateway will be quite different from the Server IP you need to have the MASK set as shown above to have it accepted.
signale-event post-upgrade; signal-event reboot
enjoy
<here would be a lot easier if we could force it to have a local IP first so you could ssh from Proxmox to SME and you could then use scp to copy files or a terminal to copy and paste>
When you go through the setup, make sure you pick the DUMMY adaptor for the local interface, and the real adaptor for the external interface. Make sure you know your MAC addresses so you know which one is which.
you can use your second IP address for the external interface, but you will have to set a subnet mask and gateway IP that it likes e.g.:
- IP : 200.30.30.1
- Subnet : 255.255.255.0
- Gateway : 200.30.30.1
One you have rebooted your network will not be working correctly so we need to follow Daniels guide to fix it :
db configuration set ExternalIP 200.30.30.1 db configuration set ExternalNetmask 255.255.255.255 db configuration set GatewayIP 62.20.20.1 /etc/e-smith/events/actions/initialize-default-databases
mkdir -p /etc/e-smith/templates-custom/etc/sysconfig/network/ echo '# GATEWAYDEV disabled for dedibox network' > /etc/e-smith/templates-custom/etc/sysconfig/network/40GATEWAYDEV echo '# GATEWAY disabled for dedibox network' > /etc/e-smith/templates-custom/etc/sysconfig/network/50GATEWAY expand-template /etc/sysconfig/network mkdir -p /etc/e-smith/templates-custom/etc/sysconfig/network-scripts/route-ethX cat <<'EOF' > /etc/e-smith/templates-custom/etc/sysconfig/network-scripts/route-ethX/20gateway { die "Need to pass THIS_DEVICE in MORE_DATA\n" unless (defined $THIS_DEVICE); my $device = $ExternalInterface{Name}; unless ($device) { warn("Can't determine device name for external network"); return "# template expansion error - Can't determine device name for external network"; } return "# Gateway only applies on external interface" unless ($ExternalInterface{Name} eq $THIS_DEVICE); my $gw = $ExternalInterface{'Gateway'}; $OUT .= "$gw dev $THIS_DEVICE\n"; $OUT .= "default via $gw dev $THIS_DEVICE"; } EOF
(See below for SME v9 configuration)
If you have got it right then you should be able to run the following without error :
expand-template /etc/sysconfig/network-scripts/ifcfg-$(db configuration getprop ExternalInterface Name) expand-template /etc/sysconfig/network-scripts/route-$(db configuration getprop ExternalInterface Name)
Check all the network settings look correct and then:
signal-event post-upgrade;signal-event reboot
You should now be able to connect to your Proxmox box on your primary IP address, and your SME server on your added IP.
Your network setting should look similar to this:
EthernetDriver1=virtio_net EthernetDriver2=virtio_net ExternalDHCP=off ExternalIP=200.30.30.1 ExternalInterface=interface Broadcast=(whatever) Configuration=static Driver=virtio_net Gateway=62.20.20.1 #gateway for your main IP address HWAddress=10:10:00:00:20:20 #MAC that you set for 2nd IP address IPAddress=200.30.30.1 #your 2nd IP address Name=eth1 Netmask=255.255.255.255 Network=200.30.30.1 #your 2nd IP address ExternalNetmask=255.255.255.255 GatewayIP=62.20.20.1 #gateway for your main IP address
Following your 'local network' and is the range when you VPN :
InternalInterface=interface Broadcast=192.168.98.255 Configuration=static Driver=virtio_net HWAddress=fe:aa:16:19:e8:bf #MAC for 'virtual' adaptor IPAddress=192.168.98.1 NICBondingOptions=miimon=200 mode=active-backup Name=eth0 Netmask=255.255.255.0 Network=192.168.98.0 LocalIP=192.168.98.1 LocalNetmask=255.255.255.0
Things have changed slightly for v9
Use the same db settings and templates as for v8.
You can make one small change to the template. Replace :
my $gw = $ExternalInterface{'Gateway'};
With
my $gw = $GatewayIP;
To update the config files you now need to run :
/etc/e-smith/events/actions/update-ifcfg signal-event post-upgrade;signal-event reboot
Note that you will not see MAC addresses in the Internal Interface settings as you did in v8
Xen
QEMU/KVM
Virtualbox
High I/O causing filesystem corruption
It seems during times of high I/O, like backups and etc, the guest filesystem resets to read-only. You can have the following errors in log
https://www.virtualbox.org/ticket/10031
Apr 30 13:37:29 sme9 kernel: ata2.00: exception Emask 0x0 SAct 0x7fffffff SErr 0x0 action 0x6 frozen Apr 30 13:37:29 sme9 kernel: ata2.00: failed command: WRITE FPDMA QUEUED Apr 30 13:37:29 sme9 kernel: ata2.00: cmd 61/08:00:08:7d:77/00:00:03:00:00/40 tag 0 ncq 4096 out Apr 30 13:37:29 sme9 kernel: res 40/00:01:00:00:00/00:00:00:00:00/00 Emask 0x4 (timeout)
the workaround is to set virtualbox to use the host I/O disk cache : see settings/storage/controller and activate the option
OpenNode
See this forum post
Example to create a SME Server 8.1-x86_64 VM :
1) you have to install OpenNode, it can be installed after a CentOS6 on cloud hosting : http://opennodecloud.com/downloads/
2) Connect to your VE :
ssh -c blowfish -X -C root@YourServerIP
3) Download SME Server ISO :
cd /storage/local/iso/ wget http://mirror.smeserver.eu/smeserver/releases/8.1/iso/x86_64/smeserver-8.1-x86_64.iso
4) Pre-create VM disk image :
qemu-img create -f qcow2 -o preallocation=metadata /storage/local/images/smeserver8vm.qcow2 10G
5) Launch installation inside screen :
screen virt-install --connect qemu:///system \ --name smeserver8vm --ram 1024 --vcpus 1 \ --disk path=/storage/local/images/smeserver8vm.qcow2,format=qcow2,bus=virtio,cache=none \ --network=bridge:vmbr0,model=virtio --vnc --os-type=linux --os-variant=rhel5 \ --cdrom /storage/local/iso/smeserver-8.1-x86_64.iso --accelerate --noautoconsole --keymap=fr
6) Detach screen :
[CTRL+A+D]
7) launch virt-manager to manage your VM
virt-manager
SME v9
Please see the forum post for instructions on v9
You will find help in the opennode's wiki and forum.
SME Server as a Host server
Phpvirtualbox
- Phpvirtualbox SME Contrib