====Standard configuration====
 
====Standard configuration====
Obtain your configuration values <br />
+
If using USB just enable nut
 +
config setprop nut status enabled
 +
 
 +
If using a serial port you have to set a Model
 
Find your model here http://www.networkupstools.org/compat/stable.html <br />
 
Find your model here http://www.networkupstools.org/compat/stable.html <br />
 
Type is only used if your model is genericups <br />
 
Type is only used if your model is genericups <br />
note. /dev/ttyS0 = com1,
 
see nut [http://www.networkupstools.org/faq/ FAQ] if using USB <br />
 
  
set configuration values
 
 
  config setprop nut Device /dev/ttyS0
 
  config setprop nut Device /dev/ttyS0
 
  config setprop nut Model apcsmart  
 
  config setprop nut Model apcsmart  
Line 20: Line 20:
 
apply changes and restart server
 
apply changes and restart server
 
  signal-event post-upgrade ; signal-event reboot  
 
  signal-event post-upgrade ; signal-event reboot  
 +
 +
alternatively
 +
expand-template /etc/sysconfig/ups
 +
expand-template /etc/ups/ups.conf
 +
expand-template /etc/ups/upssched.conf
 +
expand-template /etc/ups/upsmon.conf
 +
expand-template /etc/ups/upsd.users
 +
expand-template /etc/ups/upsd.conf
 +
upsd
 +
upsmon
  
 
confirm server is communicating with UPS
 
confirm server is communicating with UPS

Revision as of 10:11, 11 June 2007

Nut UPS – Uninterruptable Power Supply

The primary goal of the Network UPS Tools (NUT) project is to provide reliable monitoring of UPS hardware and ensure safe shutdowns of the systems which are connected.

Standard configuration

If using USB just enable nut

config setprop nut status enabled

If using a serial port you have to set a Model Find your model here http://www.networkupstools.org/compat/stable.html
Type is only used if your model is genericups

config setprop nut Device /dev/ttyS0
config setprop nut Model apcsmart 
config setprop nut Type 7
config setprop nut status enabled 

check

config show nut

apply changes and restart server

signal-event post-upgrade ; signal-event reboot 

alternatively

expand-template /etc/sysconfig/ups
expand-template /etc/ups/ups.conf
expand-template /etc/ups/upssched.conf
expand-template /etc/ups/upsmon.conf
expand-template /etc/ups/upsd.users
expand-template /etc/ups/upsd.conf
upsd
upsmon 

confirm server is communicating with UPS

upsc UPS@localhost

Emails are sent to admin whenever a UPS event occurs

Configuring as a slave

where 192.168.33.11 is your UPS master, the computer that will communicate with the UPS The hostname of the server may also work.

set configuration values

config setprop nut SlaveUPS UPS@192.168.33.11
config setprop nut Master no

apply changes and restart server

signal-event post-upgrade ; signal-event reboot 

confirm server is communicating with master

upsc UPS@192.168.33.11

Conecting multiple UPS's

to be added http://bugs.contribs.org/show_bug.cgi?id=629