We could add a section on enabling smartd to monitor disk health <br>
 
see http://bugs.contribs.org/show_bug.cgi?id=1445 <br>
 
http://www.linuxmanpages.com/man8/smartd.8.php
 
  
===Monitor Disk Health===
 
Self-Monitoring, Analysis and Reporting Technology (SMART) is built into many ATA-3 and later ATA, IDE and SCSI-3 hard drives. The purpose of SMART is to monitor the reliability of the hard drive and predict drive failures, and to carry out different types of drive self-tests.
 
 
 
To enable
 
config set smartd service
 
config setprop smartd status enabled
 
ln -s /etc/rc.d/init.d/e-smith-service /etc/rc.d/rc7.d/S40smartd
 
 
This will log warnings to /var/log/messages.
 
 
to send warning to admin. append the '''-m admin''' directive to DEVICESCAN in the config file
 
nano -w /etc/smartd.conf 
 
DEVICESCAN -m admin [-M diminishing -M test optional/test]
 