Chapter 3. Configuration Guide
For more detailed information refer to the Developers Manual
db commands
type db for usage
db
dbfiles are in /home/e-smith/db
example, db accounts show
More information about the internal configuration database of SME Server can be found in the [SME Server Developer's Guide].
Actions and Events
Actions and Events are used to apply configuration changes and most of them are fired through the panels of the server-manager. An event can consist of multiple actions.
To fire an event from the SME Server shell you simply type
signal-event event-name
To reboot your server for instance you would type:
signal-event reboot
More information about [Actions] and [Events] can be found in the [SME Server Developer's Guide].
Custom Templates
Custom templates allow for site specific overrides of normal behaviour.
Note, they are not to be used in contrib rpms, if a change is needed in the original fragment raise a bug see http://forums.contribs.org/index.php?topic=35156.0